How to Install and Mount a GP-SWR-A Inverter Remote
Installation
1. Refer to the drawing for hole and cutout dimensions for mounting below.
2. Use the cable between CR8 remote and the inverter.
3. Switch the inverter to REMO position.
GP-SWR-A Remote Control Cables
Mounting
Step 1
Cut out the template and position it on the wall where the remote is to be mounted.
Step 2
Mark the location of the two holes, and the square area to be cut out. Note: Remote switch assembly requires 0.7” (18mm) minimum clear panel depth.
Step 3
Drill two holes, 7/64” (2.8mm) diameter and remove the cutout area.
Step 4
Feed the connector and wire though the cutout hole in the panel and route the wire to the inverter receptacle (RS 232 Port).
Step 5
Position the remote switch assembly upright and secure to the panel using the two screws provided. Plug the phone jack into the inverter. Press the button to turn the inverter on and off.