Jun 17, 2022
30728
List of Error Codes
Below are two tables that identify inverter error codes, and how to remedy them.
Remote Error Codes | ||
PTOC (Over current protection) | Pulling to much current from inverter | Turn off loads, unplug from shore power, power cycle the inverter. Turn inverter back on and re-apply shore power |
OTP (Over Temperature Protection) | Inverter or batteries are to hot | Check battery connections. Is battery to hot? Remove temp sensor |
UTP (under temperature Protection) | Inverter or batteries are to cold | Warm batteries up in some way |
UVP (Under voltage protection) | Battery voltage is below Low voltage disconnect point on the inverter |
Recharge batteries above LVD set on inverter. Then turn inverter on and re-apply shore power |
OOCP (Over current protection) | Second over current message | Turn off loads, unplug from shore power, power cycle the inverter. Turn inverter back on and re-apply shore power |
OVP (Over voltage protection) | Battery volatge is to high | Unplug shore power power cycle the inverter. Run inverter without shore power to drop battery voltage. Check charge settings on all sources |
Poff (NO ac power) | NO AC input power | Check breakers and AC getting to inverter |
OLP Over Load protection | Loads to high for inverter output | Turn off loads, unplug from shore power, power cycle the inverter. Turn inverter back on and re-apply shore power. Turn loads on one by one eliminating load causing the issue |
Error Beeps From Inverter | |
Beeping counts | Protection signal |
1 beep | UTP (Under Temp Protection) |
2 beep | OTP (Over Temp Protection) |
3 beep | OVP |
4 beep | UVP |
5 beep | Short-circuit or OLP |