You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Home > Solar Kit Support > Flexible Kit Support > Reverse Blocking Diodes
Reverse Blocking Diodes
print icon

Products Affected: Flexible Solar Panels

Problem Description:

In parallel connected PV systems if all or part of a PV panel is shaded, then other unshaded parallel panels can force current through the shaded panel and cause unnecessary heating that can cause discoloration of some rooftop materials and wasted power that can reduce system performance.

Solution:

Reverse blocking diodes placed on the positive output of every parallel panel prevents unnecessary heating and improves system performance. The diagram below shows where the diodes are installed. These diodes are low cost and easy to install by simply plugging them into the existing MC4 connectors.

 

Starting soon Go Power! will be providing reverse blocking diodes in every flexible solar kit and we recommend that they are installed on every flexible solar panel. This also applies to single solar panel systems so that if an additional solar panel is added in parallel by way of an aftermarket installation, then there will be enough diodes to effectively prevent solar panels from sourcing power into other solar panels.

 

The reverse blocking diode Go Power! will be providing is shown in the image below.

 

Feedback
0 out of 0 found this helpful

scroll to top icon