You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Home > Solar Kit Support > Flexible Kit Support > Solar Flex Kits (35-200 watts): SOLAR PANELS
Solar Flex Kits (35-200 watts): SOLAR PANELS
print icon

WARNING: Photovoltaic panels generate DC electricity when exposed to sunlight or other light sources. When exposed to light, contact with the electricity active parts of the panel, such as terminals, can result in burns, sparks and lethal shock whether the panel is connected or disconnected.

 

 

 

 

 

Do not touch the terminals while the panel is exposed to light. Cover the panel faces completely with an opaque material to stop the production of electricity when working with panels or wiring – the cardboard shipping boxes are the perfect option to cover glass surface of the panels.

 

NOTE: Panels are not recommended to bend beyond 30° (for 100W Modules, 30° = 2.7”, 69mm Bend)

 

Site Considerations — Excluded Operating Environments

Certain extreme operating environments are not recommended for Go Power! products and are excluded from the Go Power! limited warranty. These include (but are not limited to): winds exceeding 45 MPH, flooding or immersion in water or other fluids, contact with liquids or substances with a pH less than 6.5 or greater than 8.5, and contact with fire, projectiles, lava flow, volcanic eruptions, or meteors.

 

Mounting Configurations

Modules installed over a roofing system must be mounted over a flat, fire-resistant roof covering with the appropriate safety rating for the application. While modules can be mounted at any vertical or horizontal angle, it is recommended that they are installed at a minimum 10-degree angle to reduce dirt accumulation and soiling.

Water entering the junction box could present a safety hazard, and junction boxes should be oriented on the uppermost position of the panel. The junction box should never be mounted in a depression. Note the junction box manufacturer rates this product with an ingress protection rating of IP67 for the box.

Modules may be attached using an adhesive on the panel backside or by using the grommet holes as attachment points. Go Power! does not recommend a preferred attachment method or make any claim as to the safety of the attachment.

Mount modules away from obstructions such as vents, AC Units, etc.

 

Module Handling

Always use gloves when handling modules. Modules are sensitive to oils and abrasive surfaces — not doing so may lead to scratching and soiling. Minimize module contact as much as possible, especially with any abrasive surfaces. Do not place anything on the modules. Do not lift modules by the cables or the junction box under any circumstances. Remove fingerprints from the panels by washing the panel as described below. 

The panels are designed to withstand a 30-degree bend top to bottom (with the junction box placed on the top end) — approximately 8cm of deflection. Care must be taken not to bend, flex, or twist panels excessively when handling. Do not place sharp objects on the panels — this may cause a puncture or damage, resulting in decreased power and creating a potential safety hazard.

Do not use blunt or sharp force with other hardware (junction boxes, cables and connectors). The resulting damage could render the module unusable.

  1. Remove shipping plastic from panel
  2. Expose the panel(s) to sunlight and use a voltmeter to test for DC Voltage
  3. Locate the solar panels on the RV roof replacing each of the boxes used in the planning step.
  4. Locate the Cable Entry Plate / Fridge Vent or Access Point on the roof.
  5. Attached the MC4 Positive and Negative Extension Cables to the solar panel(s).
  6. Test that the end solar panel cables can reach the GP-CEP / Fridge Vent or Access Point.
  7. Use the screws and washers provided in the kit to secure the solar panel to the roof.  Or an adhesive sealant can be used to attach the panels to the roof.  Please contact your vehicle manufacturer for specifications on an appropriate sealant.
  8. Apply sealant under, around and on top of each of the 6 screws to ensure a watertight installation. 

 

WARNING: Using an adhesive can create a permanent mounting situation.  It is strongly advised that placement is well thought out and that panel function has been tested before mounting.  Go Power! is not responsible for damage caused by the removal of any solar panels.

 

 

 

 

 

WARNING: The Panels must be securely fastened. Failure to do so could cause the panels to lift and separate from the surface while in transit which could cause significant damage and/or injury.

 

NOTE:
Use appropriate sealant as recommended by your RV Dealer for your RV roof.
 

Feedback
0 out of 0 found this helpful

scroll to top icon