You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
GP-MPPT Solar Controller 20-85: Operations
print icon

How to operate the GP-MPPT Solar Controller 20-85

 

Battery Charging Profile Chart

 

NOTE: Values before and after the slash correspond to 12 and 24 V systems respectively.

 

 

LED Display

 

Start Up

 

When GP-MPPT-85/20 is connected to the battery bank, the controller will start a power up mode which takes several seconds to complete.

 

LED Indicators

 

 

The green LED may flash for a few minutes after startup even if no PV is detected. This delay is to avoid erratic day/night transitions.

 

Switching Between Battery Banks

 

In some applications, two battery banks with different nominal voltages need charged from the same solar array. An external switch or relay can be used to select which battery bank is charged by the controller.

 

GP-MPPT-85/20 automatically determines nominal system voltage at startup. If there is a large jump in battery voltage (i.e. switching from one battery bank to another with a different nominal voltage), then the controller will detect the new nominal system voltage and reset.

 

WARNING: Switching must be done with an external device. Each battery bank must have a fuse or breaker. The switching circuit must not allow the battery banks to be connected/shorted.

 

Products covered in this article: GP-MPPT-20, GP-MPPT-85

Feedback
0 out of 1 found this helpful

scroll to top icon