ITEM | SEALED | GEL | FLOODED | LF1(12V) | LF2 (24V) |
---|---|---|---|---|---|
Over Voltage Disconnect Voltage | 16.0V | 16.0V | 16.0V | 14.6V | 29.2V |
Charging Limit Voltage | 15.0V | 15.0V | 15.0V | 14.8V | 28.8V |
Over Voltage Reconnect Voltage | 15.0V | 15.0V | 15.0V | 14.8V | 28.8V |
Equalize Charging Voltage | 14.6V | ------ | 14.8V | ------ | ------ |
Boost Charging Voltage | 14.4V | 14.2V | 14.6V | 14.8V | 28.8V |
Float Charging Voltage | 13.8V | 13.8V | 13.8V | 14.0V | 28.0V |
Boost Reconnect Charging Voltage | 13.2V | 13.2V | 13.2V | 13.2V | 26.4V |
Low Voltage Reconnect Voltage | 12.6V | 12.6V | 12.6V | 12.2V | 24.4V |
Under Voltage Warning Reconnect Voltage | 12.2V | 12.2V | 12.2V | 12.4V | 28.8V |
Under Voltage Warning Voltage | 12.0V | 12.0V | 12.0V | 12.0V | 24.0V |
Low Voltage Disconnect Voltage | 11.1V | 11.1V | 11.1V | 11.0V | 22.0 |
Discharging Limit Voltage | 10.6V | 10.6V | 10.6V | 10.5V | 21.0V |
Equalize Duration | 120min. | ------ | 120min. | ------ | ------ |
Boost Duration | 120min. | 120min. | 120min. | 120min. | 120min. |
1. When the battery type is sealed, gel, flooded, the adjusting range of equalizing duration is 0 to180min and boost duration is 10 to180min.
2. When setting a custom “User” battery type, (for example: a LiFePO4) use these rules when setting voltage parameters. Note LFP1 is used for 12V Lithium batteries.
LFP2 is used for 24V lithium batteries and should not be used for the DuraLite kit.
• Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.
• Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
• Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
• Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharging Limit Voltage.
• Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.