You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Home > Solar Kit Support > ECLIPSE SERIES: INSTALLING THE 30A FUSE AND FUSE HOLDER
ECLIPSE SERIES: INSTALLING THE 30A FUSE AND FUSE HOLDER
print icon

1. Locate the positive battery cable from the GP-RVC-30-MPPT.
 

2. Plan where you can safely and easily access the fuse holder & fuse.
 

3. Cut the battery positive cable from the GP-RVC-30-MPPT to the planned lengths.
 

4. Strip the fuse holder cable and positive cable from GP-RVC-30-MPPT as shown in Fig 4-F.

 

5. Thread the red heat-shrink onto the fuse holder cable.
 

6. Insert the fuse holder and GP-RVC-30-MPPT stripped cable ends into the butt splice as shown in Fig 4-G.
 

7. Crimp the butt splice fully - test the connection by gently pulling on both cables.
 

8. Thread the heat-shrink over the butt splice as shown in Fig 4-H.
 

9. Use the heat gun to shrink the heat shrink over the butt splice as shown in Fig 4-I.
 

10. Repeat the process for the other fuse holder cable & battery bank connection.

11. Do not install the 30A Fuse at this stage.

Feedback
0 out of 0 found this helpful

scroll to top icon