Various Power Modes:



Press button for more than 3 seconds and release. The battery will enter sleep mode. The LED will blink. Power off mode should only be used for long term storage or to reset the BMS. Use sleep mode to disable output power of batteries.

To prevent a surge current, perform a "pre-discharge" as outlined in the steps below:



1. Ensure all batteries are in power off mode. 

2. Connect batteries follow the series or parallel connection diagrams found at gopowersolar.com/advanced-lithiumwiring. Cable 2 must be installed for each battery pack followed by a Cable 3 cable on the last battery.

3. Ensure battery pack terminals are correctly installed and connected to the inverter system. 

4. Press the power button on one of the battery packs for 3 seconds to wake up all battery packs from Power Off mode. The LED indicator will turn on.

NOTE: Batteries are in power off mode when unboxed. Press the power button for 3 seconds to turn on. If it doesn't turn on, you will need to charge the battery. 

5. The batteries need to be configured before they can be used. Please see battery manual for instructions on battery configuration.  