ECLIPSE SERIES: INSTALLING THE 30A FUSE AND FUSE HOLDER

1. Locate the positive battery cable from the GP-RVC-30-MPPT. 2. Plan where you can safely and easily access the fuse holder & fuse. 3. Cut the battery positive cable from the GP-RVC-30-MPPT to the planned lengths. 4. Strip the fuse holder cable and positive cable from GP-RVC-30-MPPT as shown in Fig 4-F. 5. Thr…

ECLIPSE SERIES: INSTALLATION - SOLAR PANELS

SOLAR PANELS WARNING: Photovoltaic panels generate DC electricity when exposed to sunlight or other light sources. When exposed to light, contact with the electricity active parts of the panel, such as terminals, can result in burns, sparks and lethal shock whether the panel is connected or disconnected. D…

ECLIPSE SERIES: LOCATING THE GP-RVC-30-MPPT 30 AMP SOLAR CHARGE CONTROLLER

1. The GP-RVC-30-MPPT is included in the Go Power! Eclipse RV Solar Kits detailed in this manual. The GP-RVC-30-MPPT provides the necessary protection for the RV battery system. A condensed version of the installation instructions appear in this manual. However, please read the full installation manual included with …