1. The batteries communicate with each other using the RV-C ports to co-ordinate balancing. The master battery collects the information from the secondary batteries in the bank and relays the information on behalf of the entire bank of up to 32 batteries via BLE and RV-C.
2. Inter-battery communication is handled using the three cable types.
a. system harness
b. inter-battery harness
c. terminator
3. To connect and configure multiple batteries:
• connect the RV-C wires between the batteries as shown in the below diagram
• configure the batteries using the Go Power! Connect app
• the master battery can now communicate with the secondary battery/batteries
4. Configure the battery pack as follows:
a. Hold down the power button for 2 seconds or charge to wake up each battery pack, battery enters power ON mode and LED is solid light.
b. Fully charge each battery pack separately. Ensure the voltage difference between battery packs is within 1 V of each other.
c. Assign each battery pack ID one by one via mobile app and setting a master battery pack which communicate with UPS/application system, other battery packs are set for slave.
d. Press and hold power button for more than 15 seconds to shutdown battery pack. LED will turn off.
5. Refer to the connection diagram to connect the battery pack in series and/or parallel. Battery pack terminals and connection cable to be correctly installed and connected well with UPS/RV system.
6. Then press one of the battery buttons for 2 seconds or add a charger to wake up all battery packs.