You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Home > Battery Support > Advanced Lithium Support > Advanced Lithium Battery - Technical Data
Advanced Lithium Battery - Technical Data
print icon

Explore the technical specifications and features of our 100 Ah and 300 Ah lithium batteries, including voltage, capacity, temperature ranges, and more.

For the below table, all items are minimum performance values and “must have” UNLESS indicated otherwise. 
 

  100 Ah 300 Ah
Nominal voltage 12.8 V  
Nominal capacity 100 Ah 300 Ah
Cycle life 3000-5000 cycles  
Charge
Charging temperature range -20 °C … 55 °C  
Charging voltage 14.4 V Recommended (14.6 V max.)  
Recommended float charging voltage 14.1 V  
Recommended charging current 50 A 120 A
Allowed max charging current 100 A 200 A
Discharge
Discharging temperature range -20 °C … 55 °C  
Output voltage range 10 V … 14.6 V  
Max continuous discharge current 100 A max starting temp of 77 °F (25 °C) 200 A starting temp of 77 °F (25 °C)
Surge discharge current 120 A for 30m starting temp of 77 °F (25 °C) 400 A for 10m starting temp of 77 °F (25 °C)
Pulse discharge current 200 A for 5s starting temp of 77 °F (25 °C) 1000 A for 1s starting temp of 77 °F (25 °C)
Pulse discharge current 400 A for 3s starting temp of 77 °F (25 °C)  -
Low voltage end-of-discharge voltage 9.2 V± 0.1 V  
Mechanical Characteristics
Dimensions length: 304.8 mm length: 473 mm
width: 171.45 mm width: 360 mm
height: 228.6 mm height: 238 mm
Weight 11 kg 33.1 kg
Ingress Protection IP67  
Storage
Storage temperature  and humidity range 1 Week -20 °C … 50 °C, 45 % … 85% RH
1 Month -20 °C … 45 °C, 45 % … 85% RH
6 Months -20 °C … 40 °C, 45 % … 85% RH
Long term storage If the battery needs to be stored for > 3 months the voltage should be 13.2 V(50 %SOC), and stored at the storage specifications shown above. Additionally, the battery needs at least one charge & discharge cycle every six months.
BMS
Balancing balance start voltage cell≥ 3380 mV
balance start voltage difference ≥50 mV
balance off voltage difference ≤30 mV
Current charge balance current for single cell 40 mA … 50 mA
self-discharge current (active mode) ≤ 40 mA
self-discharge current (shutdown mode) ≤20 μA
max charge/discharge current 100 A/100 A
Over charge protection over charge protection voltage 3.8 V±0.02 V/cell
over charge protection delay time 2 s
over charge release voltage 3.6 V±0.02 V/cell
Over discharge protection over discharge protection voltage 2.3 V±0.1 V/cell
over discharge protection delay 2 s
over discharge release voltage min cell voltage recover to 2.8 V±0.1 Vand charging
BMS shutdown shutdown voltage min cell voltage <=2250mV
shutdown time delay 120 s
recovery charging or press button
Charge over current protection charge over current protection current 120 A±5 A
charge over current protection delay 2 s
over charging current protection release auto recover after waiting 30 s
Discharge over current protection discharge over current protection current (1) 150 A±5 A
discharge over current protection delay (1) 10 s
over current release auto recover after waiting 30 s
discharge over current protection current (2) 250 A±5 A
discharge over current protection current (2) 5 s
over current release auto recover after waiting 30 s
discharge over current protection current (3) 450 A±5 A
discharge over current protection delay (3) 500 ms
over current release auto recover after waiting 30 s
Charge over temperature protection charge high temperature protection >60±3 °C
charge high temperature release <55±3 °C
charge low temperature protection <0±3 °C
charge low temperature release >5±3 °C
Discharge over temperature protection discharge high temperature protection >80±3 °C
discharge high temperature release >61±3 °C
FET over temperature protection FET high temperature protection >110±3 °C
FET high temperature release >90±3 °C
Single cell high voltage alarm cell high voltage alarm when max cell >=3750 mV
alarm clear when max cell <=3600 mV
Single cell low voltage alarm cell low voltage alarm when min cell <=2500 mV
alarm clear when min cell >=2800 mV
High temperature alarm discharge mode: cell max temp>=75 °Cor
MOSFET temp>=105 °C
charge mode: cell max temp>=57 °Cor
MOSFET temp>=105 °C
High temperature alarm clear   cell max temp<=55 °Cor
MOSFET temp<=90 °C
Low temperature alarm min cell temp<3 °C  
Low temperature alarm clear min cell temp>= 5 °C  
Discharge current alarm discharge current>130 A  
Discharge current alarm clear discharge current<100 A  
Low SOC alarm remaining capacity <7 Ah OR min cell voltage<=2500 mV  
Low SOC alarm clear remaining capacity >=7 Ah OR min cell voltage>=2800 mV  
LED power ON mode LED solid
sleep mode LED blink
power OFF mode LED off
Reserve mode enter reserve mode battery remain capacity <5 Ah OR min cell voltage <2.5 V
exit reserve mode pack SOC>5 Ah AND min cell voltage >=2.5 V AND charging OR button pressed for 3 s
Communication CANbus and BLE protocol: RV-C with baud rate 250Kbs
Capacitor pre-charge battery pack has a pre-charge function to charge bulk capacitors in inverters to avoid surge current
Heater control auto ON 1) If cell temperature 0 °C<T<2 °C, battery is in power ON mode and pack terminal voltage >=13.8 V or charging current >10 A

2) If cell temperature T<0 °C, battery is in power ON mode and pack terminal voltage >= 13.8 V

3) If cell temperature T<2 °C and battery is in sleep mode, heater always ON
auto OFF 1) If cell temperature T<2 °C, battery is in power ON mode and pack terminal voltage <=13.5 V or discharge current for 10 s

2) If cell temperature T>=7 °C and battery is in power ON mode or sleep mode
enabled ON If cell T<2 °C
enabled OFF If cell T>7 °C
disabled always OFF  
Feedback
0 out of 0 found this helpful

scroll to top icon