IC Series Inverter/Charger: KIT PARTS AND PARTS CHECKLIST

Please unpack and make sure all parts shown in the list below are included in the IC Series Inverter/Charger kit. If any parts are missing please contact Go Power!’s customer service team at [email protected] .

IC Series Inverter/Charger: AC CONDUCTOR WIRING

Make sure the IC Series is fully disconnected from the battery bank and no AC power is connected to the Inverter/Charger before commencing any AC wiring connections. Tighten terminal blocks on both sides periodically to correct torque specs. AC INPUTS WIRING (50A Dual IN, Dual Out Configuration) * Remove the AC…

IC Series Inverter/Charger: DC OVERCURRENT PROTECTION AND DC DISCONNECT

DC OVERCURRENT PROTECTION AND DC DISCONNECT Batteries are capable of providing very large currents in case of a short circuit. If this occurs with no DC overcurrent protection, it will result in overheating and melting of the cables and possibly serious injury and/or fire. DC overcurrent protection is not include…

IC Series Inverter/Charger: DC GROUNDING

DC GROUNDING INSTRUCTORS To protect against electrical shock hazards the IC Series metal chassis must be connected to the DC grounding system. The DC grounding system is sometimes referred to as the earth ground or another designated ground. For example, on an RV, the metal frame of the RV is designated as the neg…

IC Series Inverter/Charger: WIRING THE INVERTER/CHARGER TO THE BATTERY BANK

WARNING : Lethal currents will be present if the positive and negative cables attached to the battery bank touch each other. During the installation and wiring process, ensure the cable ends are insulated or covered to prevent shorting the cables. WARNING : DO NOT connect the DC Wires from the battery bank to th…

IC Series Inverter/Charger: BATTERY TEMPERATURE SENSOR INSTALLATION

Installation Steps The Battery Temperature Sensor (BTS) extends the life of the battery by preventing overcharging in warm temperatures and undercharging in cold temperatures. The BTS provides the Inverter/Charger with precise battery temperature information to automatically adjust the absorb and float charge volt…

IC Series Inverter/Charger: GROUNDING THE INVERTER - AC GROUNDING

HOW TO GROUND THE INVERTER The IC Series Inverter/Charger should always be connected to a permanent, grounded wiring system. An Inverter/Charger system that is properly grounded will reduce the risk of electric shock, and reduce radio frequency noise. The main aim of any grounding system is to provide a well defin…

IC Series Inverter Charger: BASIC SETUP

BASIC SETUP Start the inverter first before plugging into shore power. If shore power is plugged in before the inverter is booted, if shore power is lost, the inverter will shut down. Standby Mode If the on/off switch on the inverter is applied when plugged into shore power and shore power is lost, the inverter …

IC Series Inverter/Charger: IC SERIES FAULT CONDITIONS

IC SERIES FAULT CONDITIONS The IC Series is protected against fault conditions and in normal use it will be rare to see any. If a fault condition does occur, the Inverter/Charger will shut down as a safety measure to protect itself, the battery bank, and the AC loads. The following fault conditions could be the …

IC Series Inverter/Charger: GENERAL OPERATING NOTES

GENERAL OPERATIONS INSTRUCTIONS ON/OFF SWITCH When the Inverter/Charger is first connected to the battery bank, the ON/OFF switch must be lightly pressed to turn the Inverter ON. Once the Inverter has been turned ON, pressing the ON/OFF switch turns the Inverter on and off. WARNING : The ON/OFF switch does not t…