IC Series Inverter/Charger: FINAL INSPECTION

Steps on Final Inspection 1. Verify all cables/conduit runs are secured with zip ties or other non-conductive cable clamps to prevent damage from vibration. 2. Ensure all cables that pass-through walls, bulkheads, or any other openings are protected against abrasion by using strain reliefs and/or grommets. 3. …

IC Series Inverter/Charger: BATTERY TEMPERATURE SENSOR (BTS) OPERATION

BATTERY TEMPERATURE SENSOR (BTS) OPERATION The IC Series Inverter/Charger is delivered with a battery temperature sensor. By installing this sensor, the charge voltages are automatically adapted for deviating temperature. With a BTS installed, if the temperature around the BTS is below 20°C, the absorb and float c…

IC Series Inverter/Charger: POWER SHARING MODE 2

POWER SHARING MODE 2 In generator mode : * The power required by the appliances (fridge, TV, outlets) is 3600W (30AAC x 120VAC) - 1. * Shore power (utility or generator) is connected and supplying 2400W (20AAC x 120VAC) - 2. * The inverter automatically switches on and supplies the remaining 1200W (10AAC x 120…

IC Series Inverter/Charger: DISABLING THE NEUTRAL TO CHASSIS GROUND CONNECTION

HOW TO DISABLE THE NEUTRAL TO CHASSIS GROUND CONNECTION The IC Series Inverter/Charger has the automatic neutral to ground switching feature enabled as a factory default setting. In some installations this feature must be physically disabled by disconnecting the neutral to chassis ground connection. Please consu…

IC Series Inverter/Charger: AC CONDUCTOR WIRING

Make sure the IC Series is fully disconnected from the battery bank and no AC power is connected to the Inverter/Charger before commencing any AC wiring connections. Tighten terminal blocks on both sides periodically to correct torque specs. AC INPUTS WIRING (50A Dual IN, Dual Out Configuration) * Remove the AC…

IC Series Inverter/Charger: DC GROUNDING

DC GROUNDING INSTRUCTORS To protect against electrical shock hazards the IC Series metal chassis must be connected to the DC grounding system. The DC grounding system is sometimes referred to as the earth ground or another designated ground. For example, on an RV, the metal frame of the RV is designated as the neg…

IC Series Inverter/Charger: AC POWER PASS-THROUGH MODE

AC POWER PASS-THROUGH MODE In AC power pass-through mode: * Shore power (utility or generator) is connected. * The power required by the appliances (fridge, TV, charger) is 3600W (30AAC x 120VAC) - 1. * Shore power is powering all the appliances (3600W) - 2. * Batteries are not being charged.

IC Series Inverter/Charger: BATTERY TEMPERATURE SENSOR INSTALLATION

Installation Steps The Battery Temperature Sensor (BTS) extends the life of the battery by preventing overcharging in warm temperatures and undercharging in cold temperatures. The BTS provides the Inverter/Charger with precise battery temperature information to automatically adjust the absorb and float charge volt…