The IC Series Inverter/Charger has two accessories available: * IC Series remote (not included). * Battery temperature sensor (included). IC Series Remote This remote control device can be used for monitoring the performance of the unit. It is also used to program certain settings on the Inverter, Charger, and …
TYPES OF AC POWER SOURCE AC Input power to the IC Series can be supplied from a split-phase or dual-input single phase AC source. These sources typically include utility power or a generator. • Split Phase : This source has 4 lines: 2 Hot Lines, one neutral and one ground. The 2 hot lines are 120VAC and are 180 …
BATTERY TEMPERATURE SENSOR (BTS) OPERATION The IC Series Inverter/Charger is delivered with a battery temperature sensor. By installing this sensor, the charge voltages are automatically adapted for deviating temperature. With a BTS installed, if the temperature around the BTS is below 20°C, the absorb and float c…
FACTORY DEFAULT VALUES The IC Series Inverter/Charger uses default values for the following adjustable settings: These settings are only adjustable with the GP-ICR-50 remote, which can be purchased separately from Go Power!. For detailed information on these settings please refer to the remo…
HOW TO MAINTAIN AND TROUBLESHOOT THE IC SERIES INVERTER The IC Series is designed to be service-free. Even though there are no user serviceable parts, it is recommended that every 6 months you perform the following maintenance steps to ensure optimum performance and extend the life of your batteries: * Visually …