FACTORY DEFAULT VALUES The IC Series Inverter/Charger uses default values for the following adjustable settings: These settings are only adjustable with the GP-ICR-50 remote, which can be purchased separately from Go Power!. For detailed information on these settings please refer to the remo…
Congratulations on purchasing your Go Power! IC Series Inverter/Charger. The IC Series Inverter/Charger combines the functions of a pure sine wave inverter, battery charger and AC transfer switch into one unit - saving space, installation time, and system complexity. The IC Series is designed for mobile and home po…
MOUNTING THE DRIP SHIELD The IC Series Inverter/Charger is Marine UL listed. In order to properly mount the Inverter/Charger in a marine application, you must use a drip shield. Please follow the installation instructions below. WALL MOUNT 1. Use the screws to mount the drip shield on the wall. 2. Use…
GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS SPECIFICATION Compliance with UL standards requires that Go Power! test and recommend specific GFCIs for use on the AC output of the IC Series. GFCIs shall be installed in the AC output wiring system to proceed all branch circuits. A GFCI is a device that de-energi…
INSTRUCTIONS FOR CHARGING MODE In charging mode : * Shore power (utility or generator) is connected and supplying 15AAC (1800W: 15AAC x 120VAC) - 1. * No power is required by the appliances (fridge, TV, charger). * Batteries are being charged up to 100 Amps (with the 2000W) or 125 AMPs (with the 3000W) DC pe…
AC TERMINAL BLOCK CONNECTIONS The IC Series has a six-pole AC terminal block and two AC ground terminals to connect the Inverter/Charger’s AC input and output wiring. The terminal block and ground terminals can be accessed by removing the three Phillips screws holding the AC cover plate. Each connection on the…
How to test the Installation 1. Apply battery power to the inverter by engaging the fuse, switching the breaker on or switching the battery disconnect switch to the ON position. The Inverter/Charger will remain off. 2. Disconnect all AC loads from the breaker panel by switching the main on/off breaker or all indi…
Please unpack and make sure all parts shown in the list below are included in the IC Series Inverter/Charger kit. If any parts are missing please contact Go Power!’s customer service team at [email protected] .
DC OVERCURRENT PROTECTION AND DC DISCONNECT Batteries are capable of providing very large currents in case of a short circuit. If this occurs with no DC overcurrent protection, it will result in overheating and melting of the cables and possibly serious injury and/or fire. DC overcurrent protection is not include…